Xi'an Huance Automation Technology Co., Ltd.

From HCATM, Serve the world

Manufacturer from China
Active Member
6 Years
Home / Products / Electromagnetic Flow Meter /

Clamp Type Electromagnetic Flow Meter Conductive Liquid Medium With High Precision

Contact Now
Xi'an Huance Automation Technology Co., Ltd.
City:yantai
Province/State:shandong
Country/Region:china
Contact Person:MrSimon
Contact Now

Clamp Type Electromagnetic Flow Meter Conductive Liquid Medium With High Precision

Ask Latest Price
Brand Name :HCATM
Model Number :GMF701-C
Certification :CE,RoHS
Place of Origin :Xi'an
MOQ :1
Price :$300~10000USD/pieces
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :10000 pieces per month
Delivery Time :3-5 days
Packaging Details :Packed in cardboard or wooden boxes
Medium :Conductive liquid
Accuracy :±0.5%FS
Output :4-20mA;HART;RS-485
Pipe Diameter :DN10-DN2200mm
Flow Range :0-10m/s
Power Supply :24VDC;220VAC
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

GMF701-A Water sewage seawater acid sulfuric acid 4-20mA pulse GPRS high precision electromagnetic flow meter

Product Overview

GMF701-C sanitary electromagnetic flowmeter adopts new sanitary lining material and lining technology, which meets the sanitary requirements of the food industry. At the same time, it uses stainless steel casing and stainless steel clamp connection to facilitate the rapid disassembly and cleaning of sanitary electromagnetic flowmeter The sanitary electromagnetic flowmeter is not easy to be polluted in the process of use, and can be widely used in the production process of food such as mineral water, soy sauce, jam, beer, fruit juice, rice wine, milk and other fields such as sanitation and chemical industry.

Clamp Type Electromagnetic Flow Meter Conductive Liquid Medium With High Precision

Technical Parameter

Medium Conductive liquid
Characteristics Universal
Precision ±0.5%FS
Output Pulse; frequency; 4-20mA
HART;RS-485;RS-232; GPRS
Pipe Diameter DN10-DN2200mm
Conductivity ≥5μS/cm
Lining Chloroprene rubber
Fluoroplastics (F4, F46, PFA)
Polyurethane rubber
FEP (polyperfluoroethylene propylene)
Flow Rate Range 0-10m/s
Fluid Temperature -25℃~180℃~250℃
Electrode Material 316L, Hastelloy, titanium, tantalum, etc.
Body Material Carbon steel
Installation Form Flange
Structure Type Integrated-type
Protection Level IP65,IP67,IP68
Working Environment Environmental temperature: -20 ~ +60 ° C
Humidity: 5%~95% RH
Pressure Level 1.0MPa;1.6MPa;4.0MPa
Power Supply 24VDC;220VAC
Explosion Proof Explosion-proof ExdeibmbIICT3-T6
Power Consumption 0.65W
Remarks Installation methods, pressure levels, body materials, electrode materials, lining materials, output signals, and other parameters can be customized according to different customer needs.

Product Features

1. Measurements are not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;

2. There is no obstructed flow component in the measuring tube, no pressure loss, and the requirements of the straight pipe section are low. Unique adaptability to slurry measurement;

3. Reasonable selection of sensor lining and electrode materials, that is, good corrosion resistance and wear resistance;

4. The converter adopts novel excitation mode with low power consumption, stable zero point and high precision. The flow range can reach 150:1;

5. The converter can be integrated with the sensor or separated;

6. The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting, and reliable programming;

7. The flowmeter is a two-way measuring system with three totalizers: positive total, reverse total and total difference; can display positive and negative flow, and has multiple outputs: current, pulse, digital communication, HART;

8, the converter uses surface mount technology (SMT), with self-test and self-diagnosis function;

9. Measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The sensor induced voltage signal has a linear relationship with the average flow velocity, so the measurement accuracy is high.

10. There is no obstruction in the measuring pipe, so there is no additional pressure loss; there are no moving parts in the measuring pipe, so the life of the sensor is extremely long.

11. Since the induced voltage signal is formed in the entire space filled with the magnetic field and is the average value on the pipeline surface, the sensor requires a short straight pipe section and a pipe diameter of 5 times.

12. The converter adopts the latest and most advanced single-chip microcomputer (MCU) and surface mount technology (SMT) in the world. It has reliable performance, high precision, low power consumption, stable zero point and convenient parameter setting. Click on the Chinese display LCD to display the cumulative flow, instantaneous flow rate, flow rate, flow percentage, and more.

13, two-way measurement system, can measure forward flow, reverse flow. Special production processes and high-quality materials ensure that the performance of the product remains stable for a long time.

Product Details

Clamp Type Electromagnetic Flow Meter Conductive Liquid Medium With High Precision

Inquiry Cart 0