Brand Name :HCATM
Model Number :GMF701-O
Place of Origin :XIAN
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :PIECE/WEEK
Delivery Time :3 to 7 working days after payment
Packaging Details :Carton
Lining :PTFE, rubber
Temperature :Rubber lining≤80°C PTFE lining≤120°C
Pressure :DN10- DN80≤ 4.0MPa DN100- DN150≤ 1.6MPa DN200- DN300≤ 1.MPa
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description

Electromagnetic flowmeter is an instrument that uses the principle of electromagnetic induction to measure the flow of conductive fluid based on the electromotive force induced when the conductive fluid passes through an external magnetic field.

Features
1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity;

2. There are no obstructive flow parts in the measuring pipe, no pressure loss, and lower requirements for straight pipe sections. It has unique adaptability to slurry measurement;

3. Reasonably choose the sensor lining and electrode materials, that is, it has good corrosion resistance and abrasion resistance;

4. The converter adopts a novel excitation method with low power consumption, stable zero point and high accuracy. The flow range can reach 150:1;

5. The converter and the sensor can be integrated or separated;

6. The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting and reliable programming;

7. The flowmeter is a two-way measurement system with three totalizers: forward total, reverse total and difference total; it can display positive and negative flow, and has multiple outputs: current, pulse, digital communication , HART;

8. The converter adopts surface mount technology (SMT), with self-check and self-diagnosis functions;

9. The measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The sensor induced voltage signal has a linear relationship with the average flow rate, so the measurement accuracy is high.

10. There are no obstructions in the measuring pipeline, so there is no additional pressure loss; there are no moving parts in the measuring pipeline, so the sensor has an extremely long life.

11. Since the induced voltage signal is formed in the entire magnetic field-filled space and is the average value on the pipe surface, the straight pipe section required by the sensor is shorter, and the length is 5 times the pipe diameter.

12. The converter adopts the latest and most advanced single-chip microcomputer (MCU) and surface mount technology (SMT) in the world, with reliable performance, high precision, low power consumption, stable zero point and convenient parameter setting. Click on the Chinese display LCD to display cumulative flow, instantaneous flow, flow rate, flow percentage, etc.

13. Two-way measuring system, which can measure forward flow and reverse flow. Special production technology and high-quality materials are used to ensure that the performance of the product remains stable for a long time.

Working Principle
The electromagnetic flowmeter is a flowmeter that performs flow measurement according to Faraday's law of electromagnetic induction. The advantage of the electromagnetic flowmeter is that the pressure loss is extremely small and the measurable flow range is large. The ratio of the maximum flow rate to the minimum flow rate is generally above 20:1. The applicable industrial pipe diameter range is wide, up to 3m. The output signal is linear with the measured flow rate, and the accuracy is high. It can measure the conductivity ≥5μs/cm Fluid flow of acid, alkali, salt solution, water, sewage, corrosive liquid and mud, mineral pulp, paper pulp, etc. But it cannot measure the flow of gas, steam and pure water.

Technical Parameters

Medium Ewage, water, tap water, acid, alkali, salt and other highly corrosive liquids, raw water, cooling water, paper pulp, mineral pulp, syrup, corn steep liquor, fiber pulp, grain pulp, lime milk, hydrogen peroxide, sea water, beer, wort, milk And various beverages and other conductive liquids and solid-liquid two-phase liquids.
Lining PTFE, rubber
Temperature

Rubber lining≤80°C

PTFE lining≤120°C

Pressure

DN10- DN80≤ 4.0MPa

DN100- DN150≤ 1.6MPa

DN200- DN300≤ 1.MPa

Precision 0.5% large-caliber plug-in type (level 2.5)
Powered by 24V/220V lithium battery (optional)
Display On-site display, split display
Communication method RS-485 communication
Output Pulse current 4-20mA RS485
Electrode 316L electrode, HC, titanium electrode, tantalum electrode, platinum electrode